OUTPUT Nominal Output Voltage(s) Supported 120V Frequency Compatibility 60 Hz Output Receptacles (2) 5-15R Pure Sine Wave Output No Output (Watts) 1250 Continuous Output Capacity (Watts) 1250 Peak Output Capacity (Watts) 2500 Output Voltage Regulation LINE POWER (AC): Maintains 120V nominal sine wave output from line Source. Inverter Power (AC) Maintains PWM sine wave output voltage of 120 VAC (+/- 5%) Output Frequency Regulation 60 Hz (+/- 0.3Hz) Overload Protection Includes 10A input breaker dedicated to the charging system and 12A output breaker for AC output loads. Outlet Details 2 NEMA 5-15R GFCI protected outlets
INPUT Nominal Input Voltage(s) Supported 120V AC Recommended Electrical Service DC INPUT: Requires 12VDC input source capable of delivering 127A for the required Duration (when used at full continuous capacity- DC requirements increase during Over-Power and Double-Boost operation). AC INPUT: 15A 120VAC recommended Maximum Input Amps / Watts DC INPUT: Full continuous load 127A at 12 VDC. AC INPUT 20 amps at 120 VAC with full inverter and charger load 12A max charge only) Input Connection Type DC INPUT: set of two (2) DC bolt-down terminals. AC INPUT: NEMA 5-15R GFCI input plug Input Cord Length Details DC INPUT: User supplies cabling. 6 gauge or larger (see manual) AC INPUT: attached 6ft. AC line cord with plug. Voltage Compatibility (VAC) 120 Voltage Compatibility (VDC) 12
BATTERY Expandable Battery Runtime Runtime is expandable with any number of user supplied wet or gel or AGM type batteries DC System Voltage (VDC) 12 Battery Pack Accessory (Optional) 98-121 sealed lead acid battery (optional) Battery Charge 10A / 40A (selectable) Expandable Runtime Yes
USER INTERFACE, ALERTS AND CONTROLS Front Panel LEDs Set of (6) LEDs offer continuous status information on load percentage ( 6 levels reported) and battery charge level (7 levels reported) See manual for sequences Switches 3 position on / off remote switch enables simple on / off power control plus "auto/ remote"
SURGE / NOISE SUPPRESSION AC Suppression Joule Rating 600
PHYSICAL Cooling Method Multi-speed fan Material of Construction Polycarbonate Receptacle Color White Form Factors Supported Mounting slots enable permanent placement of inverter on any horizontal surface.(see manual for additional mounting information)
LINE / BATTERY TRANSFER Transfer Time (Line Power to Battery Mode) 16.6 milliseconds (typical -compatible with many computers, servers and networking equipment -verify transfer time compatibility loads for UPS applications) Low Voltage Transfer to Battery Power In AC "auto" mode, inverter / charger switches to battery mode as line voltage drops to 75V (user adjustable to 85,95,105- see manual) High Voltage Transfer to Battery Power In AC "auto" mode, inverter / charger switches to battery mode as line voltages increases to 135V (user adjustable to 145 -see manual)
SPECIAL FEATURES Load Sensing Load sense function enables automatic inverter shutoff and startup as connected equipment is powered off and on. Front panel load sense potentiometer can be set to shutoff or turn on inverter power in response to loads of any level.
CERTIFICATIONS Certifications Tested to UL 458 (USA) and CSA (Canada)